IC-100 FC
FAST CURE 100% SOLIDS EPOXY

100% solids, two-component self-leveling epoxy coating used to restore concrete floors and enhance appearance. Can be customized with colors or metallic pigments to create opaque, glossy finishes. Offers excellent mechanical strength, chemical resistance, and resistance to crystallization.
ADVANTAGES
  • Dense surface resists bacteria and moisture, easy to clean
  • Can be recoated with excellent intercoat adhesion
  • Strong adhesion to various substrates
  • Fast-curing (as quick as 1 hour)

Item

Value

Packaging

11.35 L (3 US gal), 56.7 L (15 US gal)

Part A Color

Upon Request

Part B Color

Clear to Amber

Mixed Color

Upon Request

Recommended Thickness

Primer: 6–8 mils; Finish Coat: 8–12 mils

Coverage @ 8 mils

200 ft²/gal

Slurry (12 mils, 50% sand)

125 ft²

Trowel (24 mils, 85% sand)

60 ft²

Shelf Life

12 months (sealed, cool, dry, dark)

Mix Ratio by Volume

A:B = 2:1 (100:50)

Mix Ratio by Weight

A:B = 100:39–45

Gel Time (100 g @ 25°C)

25–30 minutes

Pot Life (100 g @ RT)

10–15 minutes

VOC

37 g/L

Solids by Weight/Volume

100% / 100%

Thinner Recommended

Xylene


Component

Clear (cP)

Color (cP)

Part A

1200–1400

1500–1900

Part B

200–400

200–400

Mix

1500–1800

2300–2500


Property

Value

Specific Gravity – Part A

1.14 (clear), 1.15–1.20 (color)

Specific Gravity – Part B

0.9–1.0

Bond Strength (ASTM D4541)

>300 psi (substrate rupture)

Hardness (Shore D, ASTM D2240)

85–90

Abrasion Resistance (ASTM D4060)

0.10 g loss (CS17, 1000g, 1000 cycles)

Tensile Strength (ASTM D638)

6500 psi

Compressive Strength (ASTM D695)

12000–13000 psi

Elongation (ASTM D638)

6–7%

Water Absorption (ASTM D570)

0.8%

Fire Rating (CAN/ULC S102, ASTM E84)

Flame Spread: 5, Smoke: 94 (Class A)


Temp

Foot Traffic

Light Traffic

Full Cure

10°C (50°F)

12 hrs

1 day

7 days

20°C (68°F)

6 hrs

1 day

5 days

30°C (86°F)

3 hrs

12 hrs

3–5 days


RESTRICTIONS
  • Substrate temperature: 15°C–30°C (59°F–86°F)
  • Relative humidity: ≤85%
  • Substrate moisture content: <4%
  • Avoid application on porous or ground-level exterior substrates
  • Protect from water, humidity, and condensation during first 24 hours
  • May discolor under UV exposure